Height (mm) | Width (mm) |
2805 | 1477 |
GLASS | METAL PRIMARY WINDOW | TIMBER PRIMARY WINDOW |
6 - 12mm | 2.84 W/m2K | 2.57 W/m2K |
6 - 12mm low-E | 1.91 W/m2K | 1.78 W/m2K |
24mm gas filled low-E sealed units | 1.52 W/m2K | 1.44 W/m2K |
24mm enhanced thermal sealed units | 1.21 W/m2K | 1.15 W/m2K |
GLASS | 50MM CAVITY | 100MM CAVITY | 200MM CAVITY |
6 - 6.4mm | 41 dB (Rw) | 45 dB (Rw) | 47 dB (Rw) |
6.8 - 7.5mm | 42 dB (Rw) | 46 dB (Rw) | 48 dB (Rw) |
8 - 10mm | 43 dB (Rw) | 47 dB (Rw) | 49 dB (Rw) |
10.8 - 12mm | 44 dB (Rw) | 48 dB (Rw) | 50 dB (Rw) |
TEST STANDARD | |
INTRUDER | N/A |
BLAST | N/A |
BALLISTIC | N/A |
FIRE | BS EN1364-1, BS EN1363-1 - 30 minute fire integrity |
To view the coupling guide and other documents available, please visit the technical downloads.